Details
The OT-2 system enables the users to run the full process starting from the sample transfer into a ready-to use prepared lysis plate up to the final transfer of the lysate into the PCR plate:
A heating unit allows the temperature lysis to be run fully hands-free. Furthermore, the robot occupies a small space (63 x 57 x 66 cm) on the lab bench and hence can be easily integrated into the workflow.
We provide a full starter package including all respective modules and pipettes to run your BACGene workflow in an automated setup.
Watch this video to learn more about lab automation and standardization with the OT-2 Liquid Handler and BACGene pathogen real-time PCR kits:
Key benefits of OT-2 Liquid Handler:
Enhanced Accuracy and Reliability- Reduction of human error – no repeated training needs
- Increased consistency between runs
- More than 2x higher productivity – per sample/hour
- Small footprint to run both lysis and PCR preparation
- Optimized resource planning
- Frees up your technician by approx. 42 min per full plate
Starter Package
- OT-2 Liquid handler
- 2 x Aluminium holder
- Heating module including Aluminum holder
- Lysis reagent holder
- 2 distinct multi-channel pipettes for up to 200 µL and 20 µL volumes to be able to run the BACGene PCR setup
Validated for use with
- BACGene Salmonella spp.
- BACGene Listeria monocytogenes
- BACGene Listeria spp.
- BACGene Listeria Multiplex
- 20 µL filter tip box (1x 96)
- 200 µL filter tip box (1x 96)
| SKU | HU0060910 |
|---|---|
| Sample Capacity | 94-samples (1 full plate – can also be mixed plate Listeria and Salmonella) |
| + 2 controls (C+/C-) | |
| Reagent Positions | Up to 3 Listeria and Salmonella lysis-buffer base + enzymes as well as respective positive controls |
| Incubation temperature | 37°C (20 min) + 95°C (10 min) |
| Accuracy/Precision | 15% at 1 µL / 5% at 1µL |
| Operating Conditions | 20 – 24°C at 40-60% humidity |
| Connectivity (OT-2) | WiFi 2.4 GHz IEEE 802.11b/g/n, USB 2.0 |
| Power Supply (OT-2) | Robot Power Input: 36 VDC, 6.1 A |
| Power Adapter Input: 100-240 VAC, 50/60 Hz, 4.0 A/115 VAC, 2.0 A/230 VAC | |
| Computer configuration (OT-2 App) | Windows 10, macOS 10.10 or later, Ubuntu 12.04 or later |
| 64-bit processor, 512 MB or RAM, 300 MB of free hard drive space for installation | |
| Dimensions | 63 cm x 57 cm x 66 cm |
| Weight | 48 kg |
| Maintenance | Cleaning and Maintenance calibration checks suggested in IFU |
| Services | Service Package – 1 x maintenance offering |